UM  > 健康科學學院
Evaluation of stationary and semi-stationary acquisitions in a dual-head multi-pinhole system for myocardial perfusion SPECT
Pengyu Yan1; Greta S. P. Mok1; Ling Chen1; Benjamin M. W. Tsui2
2016-03-10
Conference NameIEEE Nuclear Science Symposium / Medical Imaging Conference (NSS/MIC)
Source Publication2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
Conference Date8-15 Nov. 2014
Conference PlaceSeattle, WA, USA
Abstract

Previously we proposed a multi-pinhole (MPH) collimator for stationary clinical myocardial perfusion imaging (MPI) based on a dual-head clinical SPECT/CT scanner. However, artifacts from non-sufficient angular sampling were observed. This study aims to investigate different stationary MPH designs and the potential improvement in image quality by semi-stationary configurations with increased number of acquisition views. The 2 detectors were connected at ∼90° or L-mode with minimal imaging distance of 18.3 cm for MPI. We first optimized the MPH collimator parameters including pinhole number, imaging distance, collimator length, aperture size and acceptance angle by maximizing the sensitivity for a pre-determined field-of-view of 16 cm and target resolution of 1.095 cm. Based on the optimized results, a 3D analytical MPH projector was used to generate noise-free projections of (i) five stationary designs (L-mode-I to L-mode-V) and (ii) semi-stationary designs with 4 detector positions using the 4D extended cardiac torso (XCAT) phantom which was scaled to fit for 95% of Asian male population. Simulations of low energy high resolution (LEHR) collimator was used as a reference. The angle between 2 L-mode positions in the semi-stationary acquisition was evaluated from -45° to 180°. A 3D MPH ML-EM/LEHR OS-EM algorithm was used to reconstruct the MPH/LEHR data and normalized-mean-square-error (NMSE) was evaluated in a 2D ROI with 32 × 32 pixels which covered the center slice of the left ventricle. Our optimized MPH parameters are 12-pinhole, acceptance angle of 51°, aperture size of 4.65 mm, collimator length of 15.8 cm and imaging distance of 18.6 cm. The NMSE of L-mode-I was the lowest (0.3021) among all stationary designs. Semi-stationary mode with 40° rotation based on the stationary L-mode-I configuration provided the least NMSE result (0.1306) among all acquisitions which was better than the LEHR (0.2186). We concluded that semi-stationary MPH acquisition substantially improved the image quality as compared to the full stationary design as well as the conventional LEHR in MPI.

DOIhttp://doi.org/10.1109/NSSMIC.2014.7430863
URLView the original
Indexed BySCI
Language英语
WOS Research AreaNuclear Science & Technology ; Radiology, Nuclear Medicine & Medical Imaging
WOS SubjectNuclear Science & Technology ; Radiology, Nuclear Medicine & Medical Imaging
WOS IDWOS:000392917500119
全文获取链接
引用统计
被引频次[WOS]:1   [WOS记录]     [WOS相关记录]
Document TypeConference paper
专题Faculty of Health Sciences
Affiliation1.Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, China
2.Division of Medical Imaging Physics, Department of Radiology at Johns Hopkins University, Baltimore, Maryland, USA
First Author AffilicationFaculty of Science and Technology
推荐引用方式
GB/T 7714
Pengyu Yan,Greta S. P. Mok,Ling Chen,et al. Evaluation of stationary and semi-stationary acquisitions in a dual-head multi-pinhole system for myocardial perfusion SPECT[C],2016.
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Google Scholar
中相似的文章 Google Scholar
[Pengyu Yan]的文章
[Greta S. P. Mok]的文章
[Ling Chen]的文章
Baidu academic
中相似的文章 Baidu academic
[Pengyu Yan]的文章
[Greta S. P. Mok]的文章
[Ling Chen]的文章
Bing Scholar
中相似的文章 Bing Scholar
[Pengyu Yan]的文章
[Greta S. P. Mok]的文章
[Ling Chen]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。