UM
Effect of transmitter and receiver electrodes configurations on the capacitive intrabody communication channel from 100 KHz to 100 MHz
Vasi Luev, .1; Gao, Y.M.2; Pun, S.H.3; Mak, P.U.3; Vai, M.I.3; Krois, I.1; Cifrek, M.1
2014
Conference Name15th International Conference on Biomedical Engineering, ICBME 2013
Source PublicationIFMBE Proceedings
Volume43
Pages613-616
Conference Date124, 2013 - 127, 2013
Conference PlaceSingapore, Singapore
Author of SourceSpringer Verlag
AbstractIn the intrabody communication (IBC) the human body behaves as a medium that connects transmitter and receiver, which are placed directly on the skin, or are in its close proximity. The signal transmission path is closed through the human body, and the return signal path is closed capacitively through the environment. Hence, the received signal level is affected by the orientation of the transmitter with respect to the receiver, the number of ground electrodes connected to the body, the size of the receiver ground plane, and the surrounding environment. Both a transmitter and a receiver have a signal and a ground electrode, which can be connected to the human body in two ways: predominantly resistive and predominantly capacitive. In a predominantly resistive configuration, signal and ground electrodes are in a direct contact to the skin. The contact is obtained using standard Ag/AgCl electrodes, placed 2 cm apart. In a predominantly capacitive configuration, signal electrode is connected to the skin using standard Ag/AgCl electrode, and the ground electrode is a bare copper electrode placed on a plastic housing, 2 cm above the signal electrode. In this paper we measured transmission characteristics of the intrabody communication system in a frequency range from 100 kHz to 100 MHz using battery-powered network analyzer, for all four transmitterreceiver electrode configurations (resistive-resistive, capacitive- resistive, resistive-capacitive, and capacitive-capacitive), at five different distances along the arms (namely, 4 cm, 16 cm, 28 cm, 36 cm, and 120 cm). We proved that intrabody communication channel was reciprocal. The highest transmission gain was measured for capacitive-capacitive configuration, regardless of the distance between the transmitter and receiver. © Springer International Publishing Switzerland 2014.
DOI10.1007/978-3-319-02913-9_156
Language英语
全文获取链接
引用统计
Document TypeConference paper
专题University of Macau
Affiliation1.University of Zagreb, Zagreb, Croatia;
2.School of Physics and Information Engineering, Fuzhou University, Fuzhou, China;
3.University of Macau, Macau, China
推荐引用方式
GB/T 7714
Vasi Luev, .,Gao, Y.M.,Pun, S.H.,et al. Effect of transmitter and receiver electrodes configurations on the capacitive intrabody communication channel from 100 KHz to 100 MHz[C]//Springer Verlag,2014:613-616.
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Google Scholar
中相似的文章 Google Scholar
[Vasi Luev, .]的文章
[Gao, Y.M.]的文章
[Pun, S.H.]的文章
Baidu academic
中相似的文章 Baidu academic
[Vasi Luev, .]的文章
[Gao, Y.M.]的文章
[Pun, S.H.]的文章
Bing Scholar
中相似的文章 Bing Scholar
[Vasi Luev, .]的文章
[Gao, Y.M.]的文章
[Pun, S.H.]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。