UM  > 中華醫藥研究院
An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry
Wang Y.; Liu F.; Li P.; He C.; Wang R.; Su H.; Wan J.-B.
2016-07-13
Source PublicationAnalytica Chimica Acta
ISSN18734324 00032670
Volume927Pages:82-88
Abstract

Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies.

KeywordAlcohol-induced Liver Injury Multiple Ion Monitoring Pseudotargeted Metabolomics Time-staggered Ion Lists
DOI10.1016/j.aca.2016.05.008
URLView the original
Indexed BySCI
WOS Research AreaChemistry
WOS SubjectChemistry, Analytical
WOS IDWOS:000376656100009
Fulltext Access
Citation statistics
Cited Times [WOS]:25   [WOS Record]     [Related Records in WOS]
Document TypeJournal article
CollectionInstitute of Chinese Medical Sciences
Corresponding AuthorWan J.-B.
AffiliationUniversity of Macau
First Author AffilicationUniversity of Macau
Corresponding Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Wang Y.,Liu F.,Li P.,et al. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry[J]. Analytica Chimica Acta,2016,927:82-88.
APA Wang Y..,Liu F..,Li P..,He C..,Wang R..,...&Wan J.-B..(2016).An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry.Analytica Chimica Acta,927,82-88.
MLA Wang Y.,et al."An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry".Analytica Chimica Acta 927(2016):82-88.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wang Y.]'s Articles
[Liu F.]'s Articles
[Li P.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wang Y.]'s Articles
[Liu F.]'s Articles
[Li P.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wang Y.]'s Articles
[Liu F.]'s Articles
[Li P.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.