UM
Imaging viscosity and peroxynitrite by a mitochondria-targeting two-photon ratiometric fluorescent probe
Sun W.1; Shi Y.-D.1; Ding A.-X.1; Tan Z.-L.1; Chen H.1; Liu R.1; Wang R.2; Lu Z.-L.1
2018-12-10
Source PublicationSensors and Actuators, B: Chemical
ISSN09254005
Volume276Pages:238-246
AbstractThe irregular viscosity and peroxynitrite (ONOO) concentration in mitochondria would result in mitochondria disorders. However, fluorescent probes that can detect both of viscosity and peroxynitrite have not been explored. For this reason, a two-photon fluorescent molecule TP-1Bz was designed and synthesized in this work for the dual-ratiometric-imaging of viscosity and exogenous and endogenous ONOO in mitochondria. Results indicated that TP-1Bz has two emissions at 407 nm and 650 nm respectively, their ratio (I650/I407) showed linear relationship to the viscosity of the media in the logarithmic plot, and its two-photon action cross-section (Φσ) at 880 nm was increased from 1.2 GM in aqueous solution to be 86.3 GM (72-fold) in 99% glycerol. With a good targeting capability to mitochondria, TP-1Bz allowed us to measure the average viscosity in the mitochidria of HepG2 cells (73.3 cp) and the mitochondria viscosity change upon the addition of ionpores. TP-1Bz also showed the high sensitivity to ONOO (LOD close to 12.1 nM) in water/glycerol (2/3) solvent as well as the high selectivity over other ROS. With the advantages of its lower cytotoxicity, pH- and photo- stabilities, TP-1Bz was successfully employed for imaging ONOO in living cells and even in tissue samples of rat liver through the monitoring the emission intensities of the blue and red channels. As the first example of two-photon ratiometric fluorescent probe for dual-imaging viscosity and peroxynitrite in mitochondria, TP-1Bz has great potential to be developed for clinical applications.
KeywordMitochondria Peroxynitrite Ratiometric viscosity Two-photon imaging
DOI10.1016/j.snb.2018.08.045
URLView the original
Indexed BySCI
Language英語
WOS Research AreaChemistry ; Electrochemistry ; Instruments & Instrumentation
WOS SubjectChemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
WOS IDWOS:000444637600031
PublisherELSEVIER SCIENCE SA
Fulltext Access
Citation statistics
Cited Times [WOS]:13   [WOS Record]     [Related Records in WOS]
Document TypeJournal article
CollectionUniversity of Macau
Affiliation1.Beijing Normal University
2.University of Macau
Recommended Citation
GB/T 7714
Sun W.,Shi Y.-D.,Ding A.-X.,et al. Imaging viscosity and peroxynitrite by a mitochondria-targeting two-photon ratiometric fluorescent probe[J]. Sensors and Actuators, B: Chemical,2018,276:238-246.
APA Sun W..,Shi Y.-D..,Ding A.-X..,Tan Z.-L..,Chen H..,...&Lu Z.-L..(2018).Imaging viscosity and peroxynitrite by a mitochondria-targeting two-photon ratiometric fluorescent probe.Sensors and Actuators, B: Chemical,276,238-246.
MLA Sun W.,et al."Imaging viscosity and peroxynitrite by a mitochondria-targeting two-photon ratiometric fluorescent probe".Sensors and Actuators, B: Chemical 276(2018):238-246.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Sun W.]'s Articles
[Shi Y.-D.]'s Articles
[Ding A.-X.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Sun W.]'s Articles
[Shi Y.-D.]'s Articles
[Ding A.-X.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Sun W.]'s Articles
[Shi Y.-D.]'s Articles
[Ding A.-X.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.