Abstract

In recent years, algorithm based on Mathematical Morphology and wavelet transform has been proposed for ECG QRS Complex detection. However, its intensity of computation is high. This paper proposes the algorithm and hardware architecture for the whole system of QRS Complex detection based on Mathematical Morphology and Quadratic Spline wavelet transform, with implementation in Field Programmable Gate Array (FPGA). The system consists of Morphological filtering, Quadratic Spline wavelet transform and Modulus Maxima Pair Recognition modules. The parallel and pipelined architecture of system can operate in the maximum 35MHz with throughput of one sample per clock cycle. The QRS Complex detection accuracy for MIT/BIH arrhythmia database recordings and resource consumption are reported. The design is suitable for both batch processing of huge volume ECG data and real time applications for portable devices.

DOIhttps://doi.org/10.1109/IEMBS.2008.4649814
URLView the original
Indexed BySCI
Language英语
WOS Research AreaEngineering
WOS SubjectEngineering, Biomedical ; Engineering, Electrical & Electronic
WOS IDWOS:000262404501334
Fulltext Access
Citation statistics
Cited Times [WOS]:7   [WOS Record]     [Related Records in WOS]
Document TypeConference paper
CollectionUniversity of Macau
Corresponding AuthorMang I Vai
AffiliationDepartment of Electrical and Electronics Engineering, Faculty of Science and Technology, the University of Macau (Av. Padre Tomás Pereira, Taipa, Macau.
First Author AffilicationFaculty of Science and Technology
Corresponding Author AffilicationFaculty of Science and Technology
Recommended Citation
GB/T 7714
Chio In Ieong,Mang I Vai,Peng Un Mak. ECG QRS Complex Detection with Programmable Hardware[C]:IEEE,2008:2920-2923.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Chio In Ieong]'s Articles
[Mang I Vai]'s Articles
[Peng Un Mak]'s Articles
Baidu academic
Similar articles in Baidu academic
[Chio In Ieong]'s Articles
[Mang I Vai]'s Articles
[Peng Un Mak]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Chio In Ieong]'s Articles
[Mang I Vai]'s Articles
[Peng Un Mak]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.