Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system
Chen X.M.1; Pun S.H.1; Zhao J.F.2; Mak P.U.1; Liang B.D.2; Vai M.I.1
2016-05-26
Source PublicationBioMedical Engineering Online
ISSN1475925X
Volume15Issue:1
Abstract

Background: Intra-Body Communication (IBC), which utilizes the human body as the transmission medium to transmit signal, is a potential communication technique for the physiological data transfer among the sensors of remote healthcare monitoring system, in which the doctors are permitted to remotely access the healthcare data without interrupt to the patients' daily activities. Methods: This work investigates the effects of human limb gestures including various joint angles, hand gripping force and loading on galvanic coupling IBC channel. The experiment results show that channel gain is significantly influenced by the joint angle (i.e. gain variation 1.09-11.70dB, p<0.014). The extension, as well as the appearance of joint in IBC channel increases the channel attenuation. While the other gestures and muscle fatigue have negligible effect (gain variation <0.77dB, p>0.793) on IBC channel. Moreover, the change of joint angle on human limb IBC channel causes significant variation in bit error rate (BER) performance. Conclusions: The results reveal the dynamic behavior of galvanic coupling IBC channel, and provide suggestions for practical IBC system design.

KeywordBit Error Rate Galvanic Coupling Intra-body Communication Human Limb Gestures Joint Angle Muscle Fatigue
DOIhttp://doi.org/10.1186/s12938-016-0192-z
URLView the original
Indexed BySCI
Language英语
WOS Research AreaEngineering ; Engineering, Biomedical
WOS SubjectWos:000377078600001
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Universidade de Macau
2.Shenzhen Polytechnic
Recommended Citation
GB/T 7714
Chen X.M.,Pun S.H.,Zhao J.F.,et al. Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system[J]. BioMedical Engineering Online,2016,15(1).
APA Chen X.M.,Pun S.H.,Zhao J.F.,Mak P.U.,Liang B.D.,&Vai M.I..(2016).Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system.BioMedical Engineering Online,15(1).
MLA Chen X.M.,et al."Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system".BioMedical Engineering Online 15.1(2016).
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Chen X.M.]'s Articles
[Pun S.H.]'s Articles
[Zhao J.F.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Chen X.M.]'s Articles
[Pun S.H.]'s Articles
[Zhao J.F.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Chen X.M.]'s Articles
[Pun S.H.]'s Articles
[Zhao J.F.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.